Question:
Literature source [POZAR] available here:
https://www.amazon.co.uk/Microwave-Engineering-David-M-Pozar/dp/0470631554
There's also a solutions manual available here:
https://www.scribd.com/doc/176505749/Microwave-engineering-pozar-4th-Ed-solutions-manual
Answer:
Certain loads can be matched at a single frequency with just a transmission line with the correct characteristic impedance and length.
Attached MATLAB script to to calculate Z1 and L of such transmission load to match to Z0, not all loads can be matched with such simple circuit.
John BG
jgb2012@sky.com
Literature source [POZAR] available here:
https://www.amazon.co.uk/Microwave-Engineering-David-M-Pozar/dp/0470631554
There's also a solutions manual available here:
https://www.scribd.com/doc/176505749/Microwave-engineering-pozar-4th-Ed-solutions-manual
Answer:
Certain loads can be matched at a single frequency with just a transmission line with the correct characteristic impedance and length.
Attached MATLAB script to to calculate Z1 and L of such transmission load to match to Z0, not all loads can be matched with such simple circuit.
John BG
jgb2012@sky.com